Skip to content

Messages

The Messages page (System Log) shows everything dingoConfig logs: adapter connections, device reads/writes/burns, timeouts, and the info, warning and error messages sent by devices.

Item Description
Level Show only Info, Warning, Error or All
Show Debug Also show Debug messages
Source Show only messages from one source
Log to File Save messages to a CSV file in the logs folder next to the dingoConfig program

Errors are also shown as a pop-up at the bottom of the screen.

Device Messages

Device warning and error messages show the device name, Base ID, source and the 3 data values:

Front ID: 222, Src: OverCurrent 0 25 0

This example is an overcurrent on output 1 (0 = output 1) at 25A.

Common sources:

  • OverCurrent: output number and current. Warning = overcurrent, Error = output fault
  • BatteryVoltage: battery voltage (V × 10) under 10V or over 16V
  • StateOvertemp, StateError: device state changes
  • Init, Config: fatal errors, data 1 is the error number

Common Messages

Message Meaning
Firmware needs to be updated The device firmware is older than this version of dingoConfig supports. Update the firmware
Message retry / Message failed after 2 retries The device didn't answer. Check the Base ID, bitrate and wiring
Burn Failed The device couldn't save the settings